Feature
· 0.8 Output Power Factor.
· Wide Input Voltage Range.

· External Battery Bank Available.
· Smart Battery Charger Design.
· 50/60Hz Frequency Converter Mode.
· True Sine Wave Double Conversion UPS.

Model

LVP-1000

LVP-1500

LVP-2000

LVP-3000

Capacity

1000VA/800W

1500VA/1200W

2000VA/1600W

3000VA/2400W

Input

Low Line Transfer

160VAC/140VAC/120VAC/110VAC ± 5% or 80VAC/70VAC/60VAC/50VAC ± 5%

(based on load percentage 100%~80% / 80%~70% / 70%~60% / 60%~0%)

Low Line Comeback

175VAC ± 5% or 85VAC ± 5%

High Line Transfer

300VAC ± 5% or 150VAC ± 5%

High Line Comeback

290VAC ± 5% or 145VAC ± 5%

Frequency Range

40Hz ~ 70Hz

Phase

Single Phase with Ground

Power Factor

>= 0.99 @ 220VAC ~ 230VAC (input voltage)

Output

Output Voltage

200 / 208 / 220 / 230 / 240VAC or 100 / 110 / 115 / 120 / 127VAC

AC Voltage Regulation

± 3% (batt. mode)

Frequency Range

(synchronized range)

47Hz ~ 53Hz or 57Hz ~ 63Hz

Frequency Range

(batt. mode)

50Hz ± 0.25Hz or 60Hz ± 0.3Hz

Overload

100% ~ 110% : Audible warning

110% ~ 130% : UPS shuts down in 30 seconds at battery mode or transfers to bypass mode when the utility is normal

> 130% : UPS shuts down immediately at battery mode or transfers to bypass mode when the utility is normal

Current Crest Ration

3 : 1

Harmonic Distortion

<= 3% THD (linear load)

<= 6% THD (non-linear load)

<= 4% THD (linear load)

<= 7% THD (non-linear load)

Transfer Time

AC Mode to Batt. Mode : 0

Inverter to Bypass : 4ms (typical)

Waveform (batt. mode)

Pure Sine Wave

Efficiency

AC Mode

~ 85%

~ 88%

Battery Mode

~ 83%

Alarm

Battery Mode

Sounding every 4 seconds

Low Battery

Sounding every second

Overload

Sounding twice every second

Fault

Continuously sounding

Indicator

LCD Display

UPS status, Load Level, Battery Level, Input/Output Voltage, Discharge Timer, Fault

Battery

(Standard Model)

Battery Type

12V / 7AH

12V / 9AH

12V / 7AH

12V / 9AH

Numbers

3

3

6

6

Recharge Time

4 hours recover to 90% capacity (typical)

Charging Current

1.0A (max)

Charging Voltage

41.0VDC ± 1%

82.1VDC ± 1%

Battery

(Long-run Model)

Battery Type / Numbers

Depending on the capacity of external batteries

Charging Current

4.0A or 8.0A (max)

Charging Voltage

41.0VDC ± 1%

82.1VDC ± 1%

Communication

RS-232 or USB

Support WIN 2000/2003/XP/2008/7 , Linux , MAC

SNMP (optional)

Power management from SNMP manager and web browser

Environment

Humidity

20 ~ 90% RH @ 0~40C (non-condensing)

Noise

Less than 45dB at 1M

Dimension

Tower Case (DxWxH)

397 x 145 x 220mm

421 x 190 x 318mm

Rack Case (DxWxH)

420 x 438 x 88mm (2U)

580 x 438 x 133mm (3U)

Net Weight

Tower Case

13kgs

14kgs

26kgs

28kgs

Rack Case

16kgs

17kgs

29kgs

31kgs